Logo
  • LK Group
  • Contact us
  • English
    • English
    • Deutsch
    • Svenska
    • YouTube
    • LinkedIn
    • Facebook
    • Instagram
  • Products(current)
  • Support
  • News
  • About us
  • Products
    • Ball Valves
    • Capillary fittings - Copper
    • Capillary fittings - Red Brass
    • Check Valves
    • Compression fittings and support sleeves
    • Differential Temperature Controllers
    • Expansion Vessels and Safety Groups
    • Filling Valves
    • Flexible hoses
    • Flowswitch
    • Gaskets
    • Hose clamps
    • Loading Units
    • Manometers & Thermometers
    • Mixing Valves
    • Other Products
    • Prefab
    • Pressure Reducing Valves
    • Products for Underfloor Heating
    • Pump Groups
    • Pump Valves & Pump Fittings
    • Safety Valves
    • Solar Pump Units
    • Strainers
    • Temperature Controllers
    • Thermic Valves & Check Valves
    • Threaded fittings - Brass
    • Threaded fittings - Red Brass
    • Valve Actuators
    • Valves for Water Heating
    • Zone Valves
  • Support
    • 840/841 2.0
    • FAQ
      • Products
        • What is the running time of a SmartComfort
        • Can you use LK's safety valves with steam?
        • Do all LK 810 ThermoMat spare parts fit the entire range?
        • Is it possible to replace a Honeywell mixing valve with an LK 525 MultiZone with actuator?
        • Can I purchase spare parts for an Acaso 3-way valve in cast iron?
        • I have an RP 12-litre expansion vessel with the port on the long side but I can’t find this product on your website.
        • Why can’t I find the right spare part (sensor body) for my loading unit?
        • SmartComfort shunt exercise
        • I have an LK 550 where I replaced the insert. Now I can´t get out enough heat from it, can I do something about it?
        • How do I clean the filter on a LK 520 MultiFill?
        • What should I do if I have misplaced the air vent to my LK 550 AquaMix?
        • The warm water from my tap is not the correct temperature: what should I do?
        • Why is my safety valve leaking?
        • My mixing valve rotates in different directions: is there something wrong?
        • Unfortunately, I threw away the insulation for my LK 521 MultiFill: can I buy this as a spare part?
        • Can I replace my water meter console with a new version without adaption?
        • Which expansion vessel should I buy?
        • My LK SmartComfort says that the outdoor temperature sensor is missing but, as far as I know, my product doesn’t need one?
        • Is the LK SmartComfort compatible with a mixing valve from another manufacturer?
        • I want to replace my 12 litre expansion vessel: which should I choose?
        • Is it possible to upgrade LK110 to LK130 by purchasing and adding the indoor temperature controller? Or would I need to purchase the whole LK130 set?
      • Customer service
        • How much does this article cost?
        • Do you have this article in stock?
        • What is the difference between sanitary water and heating water?
        • What is the Kvs value?
        • What does HVAC stand for?
        • Where can I find technical documentation for a product?
        • If I misplace my instrument manual, how can I get hold of a new one?
        • How do I contact customer services?
        • Do you sell directly to consumers?
        • Do you sell directly to installers?
        • Do you have an order question
      • Marketing - Press
        • Where can I download your logotype?
        • What should I do when I need a product photo?
  • News
    • Fairs
      • MCE, 8-11 March 2022
    • Campaign site
  • About us
    • Community engagement
    • Opening hours
  • LK Group
  • Contact us
  1. Back
  2. Products
  3. Other Products
  4. Share
LK 700/705 AeroMat  Product image (LKA)
700 AeroMat Download image

LK 700/705 AeroMat

Technical data
Technical data
  • Working temperature: Min. 5 °C/Max. 130 °C
  • Max. working pressure: 1.6 MPa (16 bar)
  • Media 1: Water - Glycol mixture max. 50% Ethanol mixture max. 30%
  • Thread standard: G - male thread, G - female thread
  • Material, valve body: Stainless Steel EN 10088 1.4301
  • Other data: Material, ball valve: Brass EN 12165 CW617N, externally sandblasted and nickel-plated. ­Chrome ball
  • Material, sealing: P.T.F.E
LK 700 and 705 AeroMat are automatic free floating air ­vent valves suitable for heating and cooling systems where ­pressure, ­temperature or media place high performance demands on the air vent valve.
Read more
The float vent valve is mounted vertically at a high point in the ­system. The shut-off valve is to be installed first and there­after the float vent valve. The system should be flushed ­through and pressurized before mounting the float vent and ­opening the shut-off valve. Threads towards the system and the float vent are sealed in the usual manner.
The installation should be checked regularly. Sediments around the air outlet show that the float vent needs to be cleaned.

Cleaning the float vent valve
Close the shut-off valve and dismantle the float vent. ­Remove the black protective cap over the air outlet and unscrew the ­threaded union part underneath. Check that the outlet is free from impurities. If needed, clean with compressed air or ­cleaning needle. Clean the float vent by flushing it ­through with hot water from the top so that any impurities and ­sediments are removed. Reassemble the float vent valve in the reverse order.
Read less
Datasheet Variants
  • Articles
  • Technical diagrams
  • Downloads

LK 705 - Female thread

LK 705 - Female thread  Product image (LKA)
LK 705 - Female thread  Measurement drawing (LKA)
LK 705 - Female thread  Product image (LKA)
LK 705 - Female thread  Measurement drawing (LKA)
 
Article no. Dim. Note Weight (kg) Save in my item list
4845244 F ⅜”with shut-off valve 0.5

LK 700 - Male thread

LK 700 - Male thread Product image (LKA)
LK 700 - Male thread Measurement drawing (LKA)
LK 700 - Male thread Product image (LKA)
LK 700 - Male thread Measurement drawing (LKA)
 
Article no. Dim. Note Weight (kg) Save in my item list
094107 M ⅜” without shut-off valve 0.4
4845228 M ⅜” with shut-off valve 0.5
  • LK 700/705 AeroMat  Technical diagram Characteristics Download image
    LK 700/705 AeroMat  Technical diagram Characteristics
    Characteristics
Certificate/Type approval
  • CE Declaration of Conformity - Aeromat 700, 705.pdf

Variants

LK 705 - Female thread  Product image (LKA)

LK 705 - Female thread

LK 700 - Male thread Product image (LKA)

LK 700 - Male thread

Navigation
  • Products
  • Support
  • News
  • About us
  • Opening hours
Support
  • Contact us
  • Movies
  • Catalogues & Brochures
  • Tools
  • Career
  • FAQ
Follow us
  • Newsletter
  • Media center
  • LinkedIn
  • YouTube
  • Facebook
  • Instagram
LK Armatur AB

Garnisonsgatan 49
254 66 Helsingborg 
Sverige

Tel. 042-16 92 00
Fax. 042-16 92 20

info@lkarmatur.se
order@lkarmatur.se

VAT no: 556249-9508

Cookies

©Lagerstedt & Krantz AB

Our website uses cookies

We use cookies to ensure that we give you the best user experience on our website. By using our website you accept our use of cookies.

Find out more about cookies