LK Armatur LK Group English
Close

LK Group

LK 811 ThermoMat 2.0 W

LK 811 ThermoMat 2.0 W

  • Adjustable return temperature
  • Electronic regulation ensures an easy operation

LK 811 ThermoMat 2.0 W is a loading unit for heating applications with solid fuel boilers and storage tanks. The loading unit is intended to ensure a high return temperature as well as an optimal temperature st...

LK 811 ThermoMat 2.0 W

Variants

LK 811 - Female thread

LK 811 - Female thread 2 variants

Article Type Dim. Voltage A mm B mm C mm D mm E mm F mm Weight (kg) Dimensional sketch Item List
182772 without check valve F 1" 230 VAC, 50 Hz 226 205 230 290 90 130 4.2
182770 without check valve F 1¼" 230 VAC, 50 Hz 226 205 230 290 90 130 4.2

182772

Type without check valve
Dim. F 1"
Voltage 230 VAC, 50 Hz
A mm 226
B mm 205
C mm 230
D mm 290
E mm 90
F mm 130
Weight (kg) 4.2
Dimensional sketch
Item list

182770

Type without check valve
Dim. F 1¼"
Voltage 230 VAC, 50 Hz
A mm 226
B mm 205
C mm 230
D mm 290
E mm 90
F mm 130
Weight (kg) 4.2
Dimensional sketch
Item list
LK 811 - Female thread - with LK 100 SmartComfort CT

LK 811 - Female thread - with LK 100 SmartComfort CT 2 variants

Article Type Dim. Voltage A mm B mm C mm D mm E mm F mm Weight (kg) Dimensional sketch Item List
182779 without check valve + CT 100 F 1" 230 VAC, 50 Hz 277 199 227 287 87 130 4.2
182780 without check valve + CT 100 F 1¼" 230 VAC, 50 Hz 277 199 227 287 87 130 4.2

182779

Type without check valve + CT 100
Dim. F 1"
Voltage 230 VAC, 50 Hz
A mm 277
B mm 199
C mm 227
D mm 287
E mm 87
F mm 130
Weight (kg) 4.2
Dimensional sketch
Item list

182780

Type without check valve + CT 100
Dim. F 1¼"
Voltage 230 VAC, 50 Hz
A mm 277
B mm 199
C mm 227
D mm 287
E mm 87
F mm 130
Weight (kg) 4.2
Dimensional sketch
Item list

Detailed Information

Description

LK 811 ThermoMat 2.0 W is a loading unit for heating applications with solid fuel boilers and storage tanks. The loading unit is intended to ensure a high return temperature as well as an optimal temperature stratification in the storage tank, thus ­increasing the efficiency of the system. Tarring and ­condensation are prevented which prolongs boiler life.

The LK 811 ThermoMat 2.0 W is a compact design with an integrated low-energy circulating pump and a mixing valve that ­regulates on two ports. The loading unit has three ball valves to simplify installation and maintenance and an insulation to ­minimize heat loss. Three thermometers that allow for ­simple control of the loading process can be ordered as accessories.The loading unit is ­available in two versions - with or without check valve. With a check ­valve the functions described ­under phase 4 will be obtained. The loading unit is ­reversible and can easily be adapted for mounting to the right or left of the boiler. Thanks to the three ball valves any part can be changed without draining the system in case of servicing.

LK 811 ThermoMat 2.0 W is available with or without an electronic temperature controller. Mounting kits for controllers of other brands are available - see section Temperature Controllers - Mounting Kits.
Please contact our Sales Department for more information.

LK 811 ThermoMat 2.0 W is installed in the return circuit between the solid fuel boiler and the storage tank. The unit should be mounted upright with the drive-shaft of the circulating pump in a horizontal position.

The loading unit normally requires no maintenance. The installation should be checked regularly.

Technical Data

Voltage: 230 VAC, 50 Hz
Power consumption: 10-75 W, depending on pump speed
Max. boiler power: 65 kW: 20 °C ΔT
Max. working pressure: 0.6 MPa (6 bar)
Working temperature: Min. 5 °C/Max. 95 °C
Return temperature: 5-99 °C
Ambient temperature: Min. 5 °C/Max. 60 °C
Thread standard: Rp - female thread
Media: Water - Glycol mixture max. 50%
Circulating pumps: Wilo Para /6 SC FS14, Wilo Para /8 SC FS14
Material, valve body: Brass EN 1982 CB753S
Material, insulation: Expanded Polypropylene EPP

Application

LK 811 ThermoMat 2.0 W

The function of the loading unit during the different phases of heating:
1. Heat up phase

LK 811 ThermoMat 2.0 W

2. Loading phase

LK 811 ThermoMat 2.0 W

3. End phase

LK 811 ThermoMat 2.0 W

4. Self-circulation with check valve

LK 811 ThermoMat 2.0 W

With Check Valve

LK 811 ThermoMat 2.0 W

Without Check Valve

Technical Diagrams

LK 811 ThermoMat 2.0 W

Pump Characteristics, Wilo Para */8 SC FS14

LK 811 ThermoMat 2.0 W

Boiler Capacity Diagram, Wilo Para*/6 SC FS14

LK 811 ThermoMat 2.0 W

Pump Characteristics, Wilo PARA */6 SC FS14

LK 811 ThermoMat 2.0 W

Boiler Capacity Diagram - Wilo Para */8 SC FS14

Accessories & Spare parts

Article no. Article Position
187347 Wilo Para */8 SC FS14 1
187960 Wilo Para 15-130/6 SC FS14 1
095443 Cable Wilo Para 200 mm + Connector 2
095220 Connector 3
187110 Repair kit 811 4
187066 Sealing kit 811/840/841, DN 15-20 5
013025 Gasket EPDM 1½” - Ø44 x Ø27 x 2 mm 6
187021 Check valve 810 / 811 7
187022 Plug 810 / 811 8
187018 Ball valve F 1¼" 9
187019 Ball valve 28 mm 10
187017 Ball valve F 1" 11
187351 EPP Insulation, 811 12
058126 Thermometer 120 °C 13